Skip to main content

Table 3 MDRI domains and MID thresholds from the Phase 3 study of Vestronidase Alfa [17]

From: The multi-domain responder index: a novel analysis tool to capture a broader assessment of clinical benefit in heterogeneous complex rare diseases

Domain

MID threshold

6MWT

23 m and ≥ 10% change from baseline [2, 3, 5, 6, 18,19,20,21]

FVC%pred

5% absolute change or ≥ 10% relative change from baseline in FVC%pred [2, 6]

Shoulder flexion ROM

 ≥ 20 degree change of passive shoulder range of motion [2, 3, 5, 22]

Visual acuity

 ≥ 3 lines (corrected, both eyes) [23,24,25]

BOT-2 fine motor

Fine motor precision: ≥ change of 0.72

Manual dexterity: ≥ change of 1.47 [26]

BOT-2 gross motor

Balance: ≥ change of 0.57

Running speed and agility: ≥ change of 0.59 [26]

  1. 6MWT six minute walk test, FVC%pred forced vital capacity percentage of predicted, ROM range of motion, BOT-2 Bruininks–Oseretsky Test