BEFORE WLL
|
9 MONTHS AFTER WLL
|
---|
|
Value
|
% predicted
|
Value
|
% predicted
|
---|
VC
|
1,09 L
|
44
|
1,37 L
|
51
|
FRC
|
0,94 L
|
70
|
1,29 L
|
86
|
RV
|
0,49 L
|
79
|
0,69 L
|
103
|
TLC
|
1,58 L
|
55
|
2,06 L
|
65
|
FEV1
|
0,94 L/s
|
42
|
1,06 L/s
|
44
|
FEV1/VC
|
86,24%
|
102
|
77,37%
|
92
|
RV/TLC
|
31,01%
|
151
|
33,5%
|
163
|
- Pulmonary function parameters, measured one day before and about 9 months after WLL; mild restrictive impairment is present, with a slight improvement after the procedure. VC, vital capacity; FRC, functional residual capacity; RV, residual volume; TLC, total lung capacity; FEV1, forced expiratory volume in 1 second.